These phenomena appear everywhere in catalysis and describe how gas molecules “stick” to the catalyst surface.
When atoms, ions, or molecules from gases or liquids adhere to a surface, this is called adsorption (note that absorption refers to volume). More precisely, there is chemisorption, involving strong, stable chemical bonds such as CO-Pt, and physisorption, involving weak bonds such as water on oxides, which is reversible. The binding energies of chemisorption and physisorption are approximately 800 kJ/mol and 80 kJ/mol, respectively (approximately 8 eV/atom and 0.8 eV/atom, respectively). Now for a more detailed explanation:
Chemisorption:
- Chemical adsorption occurs when there is a “proper” chemical bond between the adsorbed species and the surface.
- The bonds in chemisorption are strong: covalent or ionic.
- Chemisorption is highly specific because it requires a high affinity between the surface and the adsorbed molecules.
- It also occurs at higher temperatures, as the activation energy can be overcome.
- The result of the above is the formation of a monolayer, since the adsorbate molecules form a strong bond with the surface molecules.
- Applications: Determination of the dispersion of finely divided platinum in precious metal catalysts using CO titration; oxygen capacity of Pd catalysts; and also NiO reduction with hydrogen. C&CS uses the “Autochem 2930” from Micromeritics for this purpose.
Physisorption:
- Physical adsorption is based on dipole or van der Waals forces, which are relatively weak compared to chemical bonds.
- The bond strength is low, therefore it can also be “heated out”.
- Physisorption is not very specific and can occur on a wide variety of molecules and surfaces; this leads to the following:
- Multilayer formation: Formation of several layers on top of each other on the surface.
- Physisorption occurs preferentially at lower temperatures because the molecules adhere to the surface.
- Application: Determination of the internal surface area of catalysts using the BET method, expressed in m²/g. C&CS uses the “NOVAtouch” from Anton Paar Inc. for this purpose.